Mira Zest - Post 2003 Shower Spares

MIRA-PARENT-26

Mira
Mira Zest - Post 2003 Shower Spareshover to zoom or click to enlargeclick here to view full size

Product Details

Questions and Answers
Do you have a question regarding this product? Call us on directly 0131 538 4343 or ask us a question now. ? Ask new question

Please fill out the form below to submit your question

You browser doesn't have Flash, Silverlight, Gears, BrowserPlus or HTML5 support.

You browser doesn't have Flash, Silverlight, Gears, BrowserPlus or HTML5 support.

mira zest 8.5 permanent hot water 1 Answer

Q: hi have you any idea what part I need as my shower is permanently hot and does not give out ant cold water

Submitted 24 days ago | by al, edinburgh
! Answer this question
http://www.showerdoc.com/mira-flow-regulator-assembly-7-5-8-5kw-models-439-77
A:
The above item maybe the faulty part.Answered 24 days ago | Barrie
Mira zest 1 Answer

Q: Hi,I have a mira zest which goes for a few seconds untill hot then stops then comes back on but very hot for a start it does this 3 or 4 times during having a shower?

Submitted 228 days ago | by Jonnie, Keith
! Answer this question

A: The things to check firstare:

1 That the main valve cominginto your house is fully open.

2 Then check that the valve on the line to the shower isfully open.

If these valvesare not fully open then there may not be enough water getting to your shower to cool it properly the overheatsafety device will turn the power offuntil it cools Then it all starts again

Make sure that the shower head isclean and clear, that the hose isn’t kinked (this can happen just behind thehand set where it is difficult to see) also check the inside of the hosealthough it can look OK on the outside it could have collapsed internally

The other possibility is a faultyflow/stabilizer valve not allowing the correct amount of water into the shower.

A rough check is to remove theshower head turn temperature control to fully hot the water coming out of thehose should be a bit more than a dribble then turn to fully cold and it shouldbe coming out at full flow.

Ifthere is not much difference between the two then you could have a faulty flowvalve.

Answered 227 days ago | Barrie
shower head wont stop dripping 1 Answer

Q: I have a Mira Zest shower post 2003 and it is dripping constantly from the shower head when turned off, I have taken the hose and shower head off and it is still dripping from the outlet.

Submitted 241 days ago | by "H", Manchester
! Answer this question

A:  I think you need a new flow regulator assembly

http://www.showerdoc.com/mira-flow-regulator-assembly-7-5-8-5kw-models-439-77

Answered 240 days ago | The Doc
Corrosion 1 Answer

Q: What causes a white powdery deposit around the base of the thermal trip on my Mira Zest and how can I prevent it?

Submitted 308 days ago | by Sharki, Peterborough, Cambs..
! Answer this question
A: This is a reaction caused by damp and the metals used etc and there is nothing to be done. As long as this is not causing a problem you should not bother with it.Answered 307 days ago | Barrie
Temperature Control 1 Answer

Q: I have a Mira Zest &.5 post 2003. When set to highest temperature setting, the shower fluctuates from hot to cold and back to hot. Please advise as to remedy. Thank You.

Submitted 318 days ago | by Sharki, Peterborough, Cambridgeshire
! Answer this question

A: This is called hot coldcycling

The things to check first are.

1 That the main valve coming into your house is fully open.

2 Then check that the valve on the line to the shower is fully open.

If these valves are not fully open then there may not be enough water
getting to your shower to cool it properly, the overheat safety devicewill turn
the power off until it cools, then it then it starts to heat again andso on.

Make sure that the shower headis clean and clear, that the hose isn’t kinked (this can happen just behind thehand set where it is difficult to see) also check the inside of the hosealthough it can look OK on the outside it could have collapsed internally

The other possibility is a faulty flow/stabilizer valve not allowingthe correct amount of water into the shower.


Answered 317 days ago | The Doc
Mira zest 1 Answer

Q: My Mira Zest was working perfectly and suddenly stopped working.

The flow of water stopped regardless of settings, as if maybe a fuse had blown.

The water supply around the house is functioning normally

Submitted 322 days ago | by Chris, Sheffied
! Answer this question

A: It maybe your solenoid valve, you can check it if you have a multi meter, you shouldhave a reading of at least k3.5 ohms, across the two terminals any less and youneed a new valve. (Check the valve in the failed state.) (When it has stoppedworking!)

If thereis power getting to the solenoid and it is not operating then there is a goodchance that you have a faulty solenoid.

http://www.youtube.com/watch?v=NzJjzWqxesc

The video is intended as a guide and does not cover every shower.

If youdon’t have a multimeter we sell them with a guide on how to usethem for checking and testing the various parts of your shower.

Apart from helping to fix your shower, they are really useful forchecking you have a power supply to appliances, for checking fuses and lettingyou know much power you have left in batteries

(So youwill know if they are good or not) and lots of other jobs, in short they arewell worth a few pounds

http://www.showerdoc.com/installation/electrical-products/SKYTRO-600-005-Digital-Multi-Tester

Answered 321 days ago | Barrie
Mira Shower part replacement 1 Answer

Q: I have model Mira Zest 7.5/8.5 which is leaking very slowly from the bottom of the unit. Do I need the Mira Spare Zest Base Unit - 439.72 which I think costs over £100 +?

Submitted 353 days ago | by Jeannie, East Yorkshire
! Answer this question

A: Ithink the Pressure Relief Device (PRD) has blown.

It’sa safety device on the bottom of the heating tank.

Itis fairly easy to replace however there is usually something that causes it toblow, oftena kink in the hose or the showerhead is blocked, so check this before fittingthe new PRD.

http://www.showerdoc.com/mira-tank-outlet-and-ball-439-99

Replacing the above etc should help.

Answered 353 days ago | Barrie
heater tank 1 Answer

Q: is the trip assembly included with the heater tank

Submitted 360 days ago | by chick, n.yorkshire
! Answer this question

A: No it is a separate part

Answered 359 days ago | The Doc
New Casing Mira Zest 1 Answer

Q: The fixing points to attach the front panel to the casing have broken. Is it possible to purchase a new casing for my Mira Zest shower.

Submitted 407 days ago | by Danny, Leighton Buzzard Beds.
! Answer this question
A: Unfortunately for some reason Mira will not sell rear casings.Answered 406 days ago | The Doc
temparature control 1 Answer

Q: when the shower is set to cold it is still coming out near boiling

Submitted 410 days ago | by Anonymous, perth
! Answer this question

A: Forgetting about the temperature turn the showerfrom fully hot to fully cold at fully hot you should have not much more than adribble coming from the hose and on fully cold you should have a good strongflow, if you do not have this difference then you may have a faultyflow/stabilizer valve.

Answered 409 days ago | Barrie
mira zest electric shower latest model 1 Answer

Q: hi

when showering the unit has now got where it needs to be on full to get any heat out of it,the heat you get is above luke warm but by no means warm any ideas?

thank you

Submitted 446 days ago | by cbminis, yorkshire
! Answer this question

A: It maybe a faulty element in the heating tank (there are two, three in most 10kwshowers) you can check them with a multi meter you should have a reading ofaround 12>18 ohms.

If you have power to the elementsand no heat it's probably the elements, no power to the elements thenit's probably a micro switch.

This Video may help

http://www.youtube.com/watch?v=wzPt1hsfVq4cv

If you don’t have amultimeter  we sell them at around £10 each with a link to an on line guideon how to use them for checking and testing the various parts of your shower.

Apart from helping to fix yourshower, they are really useful for checking you have a power supply toappliances, for checking fuses, letting you know much power you have left inbatteries

(so you know if they are dud ornot)  and lots of other jobs, in short they are well  worth the £10.

http://www.showerdoc.com/installation/electrical-products/SKYTRO-600-005-Digital-Multi-Tester

Answered 444 days ago | The Doc
No Hot Water 1 Answer

Q: Hi, I have the switch to high and the temp control fully clockwise and the water is only just warm..

Since the shower was installed a few years ago it has only ever produced hot water on the high setting..

Submitted 532 days ago | by Rob, Devon
! Answer this question

A: It may be a faulty elementin the heating tank (there are two, three in most 10kw showers) you can checkthem with a multi meter you should have a reading of around 12>18 ohms.

If you have power to theelements and no heat it's probably the elements, no power to the elements thenit's probably a micro switch.

If you don’t have amultimeter we sell them at £10 each with a guide on how to use them forchecking and testing the various parts of your shower.

Apart from helping to fixyour shower, they are really useful for checking you have a power supply toappliances, for checking fuses, letting you know much power you have left inbatteries

(so you know if they are dud ornot) and lots of other jobs, in short they are well worth the £10.

http://www.showerdoc.com/installation/electrical-products/SKYTRO-600-005-Digital-Multi-Tester

Answered 532 days ago | Barrie
Mira shower front 1 Answer

Q: I have a Mira zest showe postr 2003 I want to replace the front cover can you get it in chrome or silver

Submitted 567 days ago | by Michelle, Newcastle upon tyne
! Answer this question

A: I am afraid that the Zest cover is only available in white

Answered 567 days ago | The Doc
Shower Leak 1 Answer

Q: The shower is leaking at the joint between part 4 and part 5

Submitted 577 days ago | by Ben, Barnsley
! Answer this question
Replace item "B" as shown on the diagram.
A:
http://www.showerdoc.com/shower-spares/mira/mira-parent-26-mira-zest---post-2003Answered 577 days ago | Barrie
Zest Cuts out 1 Answer

Q: Hi, I suspect I know the answer, but looking for a confirmation.



Mira Zest 8.5 post-03, works then switches off intermittently, traced the voltages through the unit and everything appears to be correct, except the 2 main power switches are not being made when the knob is turned to the on position. the 3rd switch giving power to the flow regulator is OK.



is this likely to be the main switch or the flow regulator?



Many thanks.



Dale.

Submitted 654 days ago | by thefastone, Aberdeen
! Answer this question
mira zest post 2003 1 Answer

Q: hi my shower has just stopped when switching on the rotating switch.

I have checked the electric supply to internal switch but there are terminals i ssume on the outgoing side of switch where there is no volts when switch is turned is this your no 1 switch do you nthink

Submitted 663 days ago | by nick, cornwall
! Answer this question
You should have power at item 6 on the diagram, if no you have a tripped mcb a blown fuse or the switch to the shower is faulty. If there is [power here then,
A:

It may be your solenoid valve, you can check it if you have a multi meter, you should have a reading of at least k3.5 ohms, across the two terminals any less and you need a new valve. (Check the valve in the failed state.) (When it has stopped working!)

If there is power getting to the solenoid and it is not operating then there is a good chance that you have a faulty solenoid.

http://www.youtube.com/watch?v=NzJjzWqxesc

The video is intended as a guide and does not cover every shower.

If you don’t have a multimeter we sell them with a guide on how to use them for checking and testing the various parts of your shower.

Apart from helping to fix your shower, they are really useful for checking you have a power supply to appliances, for checking fuses and letting you know much power you have left in batteries

(So you will know if they are good or not) and lots of other jobs, in short they are well worth a few pounds

http://www.showerdoc.com/installation/electrical-products/SKYTRO-600-005-Digital-Multi-Tester

Answered 661 days ago | Barrie
Mira Zest Service Tunnel 1 Answer

Q: Hi, My service tunnel has just fallen apart this morning and I can't see where the spring goes that fell out of it - can you help?

Submitted 666 days ago | by Angela, Stockport
! Answer this question

A: ??? To my knowledge there isn’t a spring in the service tunnel

http://www.showerdoc.com/shower-spares/mira/electric-showers/mira-439-95-mira-service-tunnel-439-95

Answered 666 days ago | The Doc
Mira zest weak pressure 1 Answer

Q: The pressure of my shower is terrible! I I take it off te hook to use its even worse. I can now barely wash my hair! The taps etc all run well just the shower? There is a switch in the airing cupboard which I have turned on but makes no difference? Any ideas? Thanks

Submitted 675 days ago | by Lex, Bristol
! Answer this question
You first need to make sure that there is power getting to the shower, then check that all valves are open and filters unclogged.
A: If all is well here then,

forgetting about the temperature turn the shower from fully hot to fully cold at fully hot you should have not much more than a dribble coming from the hose and on fully cold you should have a good strong flow, if you do not have this difference then you may have a faulty flow/stabilizer valve.


Answered 675 days ago | Barrie
Mira Zest 1 Answer

Q: Does the front panel, part no. 439.81 include the knobs, it's only the knobs that I need.

Submitted 796 days ago | by Mike, Macclesfield
! Answer this question
A: Part 10 comes as one unit, knobs included.Answered 794 days ago | Barrie
mira zest stopped 1 Answer

Q: hi there,i have a mira zest and a few months ago it just stopped,then if you turned it on nothing would happen for a few minites then it would fire up.Now it has packed up completly.Thanks julian

Submitted 827 days ago | by Anonymous, cornwall
! Answer this question

A: I think you need a new flow regulator assembly

http://www.showerdoc.com/MIRA-439-77-Mira-Flow-Regulator-Assembly-(7-5---8-5kw-Models)-439-77

Answered 826 days ago | The doc
runs warm then cold 1 Answer

Q: My shower runs at the set temp for about a couple of minutes then the water turns ice cold for about a minute then returns back to the right temp. This happens throughout having a shower.

Submitted 851 days ago | by Stan, Newcastle
! Answer this question
Would suspect the therrmal trip has become over sensitive , replacement can be ordered online by clicking on this link.
A:
http://www.showerdoc.com/shower-spares/mira/MIRA-439-90-Mira-Thermal-Trip-Assembly-439-90Answered 850 days ago | Alastair
No hot water 1 Answer

Q: the water won't run hot on any setting but good flow of cold runs.

Submitted 869 days ago | by Jake, Rutland
! Answer this question

A: Sorry for the delay in replying.


I think you may have a faulty Thermal Cut Out



A faulty TCO will have no continuity across the two terminals (The black thing on top of the heating tank)

Therefore a good TCO will have power at both connections and a faulty TCO will have power at only one.

(The function of the TCO is, if the water over heats it cuts the power off to the elements until the water cools, this can take up to 15mins)

See Video.

http://www.youtube.com/user/showerdoc#p/u/2/_zi8JbEMYMs

If the TCO is OK then you probably need a new flow regulator assemblyAnswered 863 days ago | The doc
Cold water flow 1 Answer

Q: After a water stoppage, the mira zest unit has waterflow but the water is not heating on any temp setting. Mains supply is fine. The flow seems very slow.



I have checked the filter, it is clear. Cable connection appear sound.

Submitted 924 days ago | by markus, gloucestershire
! Answer this question

A: If you are happy that the water supply to the unit is OK then you are going to need a new flow regulator

http://www.showerdoc.com/shower-spares/mira/MIRA-439-77-Mira-Flow-Regulator-Assembly-(7-5---8-5kw-Models)-439-77

Answered 924 days ago | The Doc
Mira Zest 8.5 pull cord light going out 1 Answer

Q: Similar to last question and probably same answer. My zest 8.5 is just 18mth old and has stopped dead. There is power to the terminal block and heater as indicated by my finger on the top, light up screwdriver!!

Just one disturbing thing, the pull cord indicator light goes out when the shower knob turned to on and comes back on when turned back. Screwdriver says power still at power terminal block when light is out. Have checked wiring in pull cord switch and all seems ok. Is this relevant?

Submitted 983 days ago | by Kris, Islay
! Answer this question

A: The pull cord switchis faulty and needs replaced.

http://62.128.217.164/electrical-products/ELWBG002-45-Amp-Ceiling-Switch

Answered 982 days ago | The Doc
mira zest nothing happens 1 Answer

Q: I have a mira zest 7.5kw got it about 3yrs ago. when i turn it on nothing happens, i have had the front cover off and tested to see if theres electric at the strip connector. I have a supply there and also at the heating element any suggestions

Submitted 984 days ago | by problem shower, durham
! Answer this question

A: I think you need a new flow regulator.

http://www.showerdoc.com/shower-spares/mira/MIRA-439-77-Mira-Flow-Regulator-Assembly-(7-5---8-5kw-Models)-439-77

Answered 983 days ago | The Doc
Shower wont switch off 1 Answer

Q: Water continues to flow even if switched off.

Is a new flow regulator required?



Steve

Submitted 1006 days ago | by steve, Carmarthen
! Answer this question

A: Yes you need a new flow regulator assy.

http://www.showerdoc.com/shower-spares/mira/MIRA-439-77-Mira-Flow-Regulator-Assembly-(7-5---8-5kw-Models)-439-77

Answered 1004 days ago | The Doc
Mira Zest Tempature problem 1 Answer

Q: My shower is either cold or boiling hot with nothing in between, can you please advise what part is required to rectify this problem

Submitted 1018 days ago | by Rick, Wiltshire
! Answer this question

A: The things to check first are.

1 That the main valve coming into your house is fully open.

2 Then check that the valve on the line to the shower is fully open.

If these valves are not fully open then there may not be enough water
getting to your shower to cool it properly the overheat safety device will turn
the power off until it cools Then it all starts again

Make sure that the shower head is clean and clear, that the hose isn’t kinked (this can happen just behind the hand set where it is difficult to see) also check the inside of the hose although it can look OK on the outside it could have collapsed internally

If all the above are OK then you are going to need a new flow valve

http://www.showerdoc.com/shower-spares/mira/MIRA-439-77-Mira-Flow-Regulator-Assembly-(7-5---8-5kw-Models)-439-77

Answered 1017 days ago | The Doc
shower head 1 Answer

Q: do you have spare shower rail and head holder

Submitted 1047 days ago | by tonym, rugby
! Answer this question
If you click on the link below it will take you to the Mira rail kit selection and you can order the one you would like online.
A:
http://www.showerdoc.com/shower-accessories/rail-kits/miraAnswered 1046 days ago | Alastair
Water leak Zest 8.5 kw 1 Answer

Q: The shower was turned off when operating on cold and it started leaking. I can see cracking on a clamp between where the filter (3) is and the flow regulator assembly (4), Is it likely to be only the clamp which has failed?



Cheers

Paul

Submitted 1090 days ago | by Big Pauly, Durham
! Answer this question

A: The only way to be sure is to undo the clamp and see, if the back box is cracked then you will have to buy a new shower because Mira will not sell back boxes.

The most common reason for the clamp cracking is that the pipe is not entering the shower perfectly squarely

Answered 1087 days ago | The Doc
Mira zest water leak 1 Answer

Q: Water is leaking from where the filter (Part3) connects to the flow assembly (part4) how do these parts connect, and are they fairly straight forward to replace?

many thanks.

Submitted 1096 days ago | by jwc_007, Devon
! Answer this question

A: Yes this should be fairly straight forward.

However......,... The reason that this part often leaks is when the shower was installed the fitter did not hold against himself when tightening the nuts, or the more usual fault is the pipe work is not entering the shower perfectly straight If this is the case you will have to try to adjust it or the same fault may occur again.

Answered 1095 days ago | The Doc
Mira zest post 2003 stops working after several minutes 1 Answer

Q: My Mira zest (post 2003) runs fine for several minutes and then just cuts out. I need to wait a while to start it again and it will run fine then stop again. I replaced the thermal trip assembly which I bought last week but the problem is still there. Do I change the switch assembly or the flow regulator assembly next. Pressure is fine going into the shower.

Submitted 1122 days ago | by Shaw70, Alloa
! Answer this question

A: I think you have a faulty flow regulator assembly.

http://www.showerdoc.com/shower-spares/mira/MIRA-439-77-Mira-Flow-Regulator-Assembly-(7-5---8-5kw-Models)-439-77Answered 1121 days ago | The Doc
Mira zest shower part 'Clamp' 1 Answer

Q: I need the the clamp thats marked c on your diagram which is the screw bracket that connects 2 to 4

Submitted 1125 days ago | by Nick, Poole Dorset
! Answer this question
Mira Zest in op 1 Answer

Q: I have a mira Zest shower that has stopped working no water is comming through to the shower head. there

appears to be 230 volts at the solenoid could this be faulty

Submitted 1188 days ago | by Mick, Edinburgh
! Answer this question

A: Here is how to check the solenoid.

It may be your solenoid valve, you can check it if you have a multi meter, you should have a reading of at least k3.5 ohms, across the two terminals any less and you need a new valve. (Check the valve in the failed state.) (When it is not working!)

If there is power getting to the solenoid and it is not operating then there is a good chance that you have a faulty solenoid.

If you don’t have a multimeter  we sell them  with a guide on how to use them for checking and testing the various parts of your shower.

Apart from helping to fix your shower, they are really useful for checking you have a power supply to appliances, for checking fuses and letting you know much power you have left in batteries

(So you will know if they are good or not) and lots of other jobs, in short they are well worth a few pounds

http://www.showerdoc.com/installation/electrical-products/SKYTRO-600-005-Digital-Multi-Tester

 

If the solenoid is faulty then I would advise replacing the complete flow valve.

Answered 1186 days ago | The Doc
Customer Reviews
Zest 8.5
Sent in a query, got a reply from michael within the hour. Ordered the part suggested (flow regulator assembly) for £28 (inc postage) that afternoon. Arrived the next day with handy instructions. Installed in about 30 mins (cleaned connections at the same time) and the shower is working as before.

Great service and great price. Would definitely use again! Pockets, Aberdeen
15 February 2011 Rating:     
Replacement Products
Current product direct changeover
Mira
RRP: £205.20 (inc. VAT)Our Price £138.00 (inc. VAT)Save £67.20
View Item
Current product direct changeover
Mira
RRP: £199.20 (inc. VAT)Our Price £141.60 (inc. VAT)Save £57.60
View Item
Related Spares

Please call for more information on available spares for this product