Q: As I turn the water temp up the flow goes down so by the time its warm enough to use the water flow is practically zero! What causes this and how can it be rectified please?
|
|
|
Submitted 69 days ago | by
phil-nick, Bristol
A: Firstcheck that the shower head is clean and clear also check the hose, theycan look OK on the outside but they can collapse internally. If these are both OK then there are filters in the shower you will have to remove these and make sure that these are clean.
Make sure you turn the water and power off first! Answered 67 days ago | Barrie
|
|
|
Q: are the parts marked G available
|
|
|
Submitted 73 days ago | by
dave, leigh
Answered 72 days ago | The Doc
|
|
|
Q: mira play shower stopped working /no water but the light stays on
|
|
|
Submitted 79 days ago | by
jase, ws71nq
A: http://www.showerdoc.com/shower-spares/mira/MIRA-1539-350-Mira-Flow-Regulator-Assembly-1539-350 It may be your solenoid valve, you can check it if you have a multi meter, you should have a reading of at least k3.5 ohms, across the two terminals any less and you need a new valve. (Check the valve in the failed state.) (When it has stopped working!) If there is power getting to the solenoid and it is not operating then there is a good chance that you have a faulty solenoid. http://www.youtube.com/watch?v=NzJjzWqxesc The video is intended as a guide and does not cover every shower. If you don’t have a multimeter we sell them with a guide on how to use them for checking and testing the various parts of your shower. Apart from helping to fix your shower, they are really useful for checking you have a power supply to appliances, for checking fuses and letting you know much power you have left in batteries (So you will know if they are good or not) and lots of other jobs, in short they are well worth a few pounds http://www.showerdoc.com/installation/electrical-products/SKYTRO-600-005-Digital-Multi-Tester Answered 77 days ago | Barrie
|
|
Q: After switching the shower off a considerable amount of water keeps dribbloing out. Does the solenoid when energised allow water through and if that is the case is it the valve not seating properly that is the problem. Can you replace the spring and diapragm separately without buying the whole solenoid assembly.
Thanks
|
|
|
Submitted 104 days ago | by
Nugget, warwickshire
A: Yes the solenoid is the part that turn the water on and offhowever it is not repairable it needs to be replaced Answered 102 days ago | The Doc
|
|
|
Q: brushes are out of stock how much are they an when will they be in
|
|
|
Submitted 121 days ago | by
Anonymous, n. Ireland
Answered 120 days ago | The doc
|
|
Q: Are the brushes on the Mira Event XS' motor replaceable? If they are do you have them in stock?
Regards
Patrick
|
|
|
Submitted 138 days ago | by
Patrick, Worthing
Answered 137 days ago | The Doc
|
|
|
Q:
|
|
|
Submitted 198 days ago | by
Rob, Unknown
A: It may be your solenoid valve, you can check it if you have a multi meter, you should have a reading of at least k3.5 ohms, across the two terminals any less and you need a new valve. (Check the valve in the failed state.) (When it has stopped working!) If there is power getting to the solenoid and it is not operating then there is a good chance that you have a faulty solenoid. http://www.youtube.com/watch?v=NzJjzWqxesc The video is intended as a guide and does not cover every shower. If you don’t have a multimeter we sell them with a guide on how to use them for checking and testing the various parts of your shower. Apart from helping to fix your shower, they are really useful for checking you have a power supply to appliances, for checking fuses and letting you know much power you have left in batteries (So you will know if they are good or not) and lots of other jobs, in short they are well worth a few pounds http://www.showerdoc.com/installation/electrical-products/SKYTRO-600-005-Digital-Multi-Tester Answered 197 days ago | The Doc
|
|
Q: Hi there, have cleaned all filters out they are like new, but still no water, pump running. Also ran water through shower with filters out, and there was plenty of water, Could the pump be faulty.
|
|
|
Submitted 206 days ago | by
nopumpy, Nottingham
A: If the pump is running and and you have no water then it is likely to be the solenoid See below for how to check. It may be your solenoid valve, you can check it if you have a multi meter, you should have a reading of at least k3.5 ohms, across the two terminals any less and you need a new valve. (Check the valve in the failed state.) (When it has stopped working!) If there is power getting to the solenoid and it is not operating then there is a good chance that you have a faulty solenoid. http://www.youtube.com/watch?v=NzJjzWqxesc The video is intended as a guide and does not cover every shower. If you don’t have a multimeter we sell them with a guide on how to use them for checking and testing the various parts of your shower. Apart from helping to fix your shower, they are really useful for checking you have a power supply to appliances, for checking fuses and letting you know much power you have left in batteries (So you will know if they are good or not) and lots of other jobs, in short they are well worth a few pounds http://www.showerdoc.com/installation/electrical-products/SKYTRO-600-005-Digital-Multi-Tester Answered 205 days ago | The doc
|
|
|
Q: the switch fails to work as the plastic piece inside has broken so the switch does not push out again ready for use. Is there a replacement part for this ?
|
|
|
Submitted 276 days ago | by
alan, holmfirth
Answered 275 days ago | The Doc
|
|
|
Q:
|
|
|
Submitted 291 days ago | by
NONeill, Dublin, Ireland
Answered 291 days ago | The Doc
|
|
Q: Hi
I would like to purchase a bottom 'Full Case Insert' can you advise on availability.
Also the oval start/stop keeps popping off can you advise on availability.
Thank you.
|
|
|
Submitted 315 days ago | by
Paul, Derbyshire
Answered 312 days ago | The doc
|
|
Q: Shower runs ok for 30-40 seconds then flow reduces to a trickle.
Temp control seems ok.
Flow control sounds like it is trying to do something but no effect.
Off/on flow ok but only for a few seconds
|
|
|
Submitted 327 days ago | by
Billy, Nuneaton
Answered 327 days ago | Alastair
|
|
Q: Water only runs hot even when turned to full cold.
|
|
|
Submitted 361 days ago | by
Tam, Glasgow
Answered 359 days ago | Alastair
|
|
|
Q: Water constantly dribbles from the showerhead even when the shower is off (started doing this a few days ago). The solenoid valve was replaced 12 months ago. Is it likely to be something else or does the valve need replacing again
|
|
|
Submitted 458 days ago | by
wetboy, Derby
Answered 457 days ago | Alastair
|
|
|
Q: Its not the showerhead cos I disconnected that, the motor runs fine (tho there is black dust from the brushes all over) but just a dribble of water comes through. its a hard water area and the showers been in about 5 years. Is there a filter thats got blocked ? where do i get those tools to undo the star shaped screwheads ?
|
|
|
Submitted 572 days ago | by
Dribbler
Answered 568 days ago | The Doc
|
|
|
Q: i cannot get the water to pump through properly
|
|
|
Submitted 604 days ago | by
puppydog
A: Would check that inlet filters are clean and that hose is not kinked or collapsed internally and that shower head is clear. Answered 602 days ago | Alastair
|
|
|
Q: Please can you tell me which sliding holder i need for our events XS power shower Thanks
|
|
|
Submitted 654 days ago | by
lizzy
A: You will find that either the Response holder MIRA-411.23 or logic holder MIRA-450.16 will be the one you require. These holders can be found by entering the part number in to the search bar at the top right of our homepage or by going in to the shower accessories tap and slider brackets on the homepage Answered 653 days ago | SD
|
|
Q: We have had the Mira Event XS for approx 2 years and all has been well until about 4 months ago it started to play up.
Turn the shower on to a average temperature and it works fine, as soon as you turn the temparture up, the shower tries too pump harder but the water decreases in pressure and the temperature drops to cold.
Turn the temperature back to average again and is back to normal, can you help.
|
|
|
Submitted 740 days ago | by
Dave
|
|
Q: Hi
We have the above shower unit, about 3 years old now. Recently when we try and take a shower the water comes through ok but starts to get very hot. When you try and turn the temperature knob to allow more cold water into the mix, the cold water eventually stops flowing. In the end no hot or cold water comes outs the shower head, you can just hear the motor running. When you turn the knob back down to allow more hot water, it comes out very hot, but once again no cold water flows.
Please can you help ?
Thankyou
|
|
|
Submitted 760 days ago | by
May
A: Hi First check that the shower head is clean and clear also check the hose, they can look OK on the outside but they can collapse internally. If these are both OK then there are filters in the shower you will have to remove these and make sure that these are clean. See attached Make sure you turn the water and power off first! Answered 759 days ago | The Doc
|
|
|
Q: I can hear the motor runnung, I've cleaned the filter but I haven't got any water coming through the shower. Any ideas
|
|
|
Submitted 791 days ago | by
Andy1877
A: Sorry for the delay in replying it sounds like a faulty solenoid valve, see below. It may be your solenoid valve, you can check it if you have a multi meter, you should have a reading of at least k3.5 ohms, across the two terminals any less and you need a new valve. (Check the valve in the failed state.) (When it is not working!) If there is power getting to the solenoid and it is not operating then there is a good chance that you have a faulty solenoid. If you don’t have a multimeter we sell them with a guide on how to use them for checking and testing the various parts of your shower. Apart from helping to fix your shower, they are really useful for checking you have a power supply to appliances, for checking fuses and letting you know much power you have left in batteries (So you will know if they are good or not) and lots of other jobs, in short they are well worth a few pounds http://www.showerdoc.com/installation/electrical-products/SKYTRO-600-005-Digital-Multi-Tester Answered 778 days ago | The Doc
|
|
|
Q: Whilst Showering, the shower runs ok but after approx 5 mins the water stops coming through the shower head. The pump still runs but no water comes through. After 15 minutes or so we can turn on and start all over again.
|
|
|
Submitted 823 days ago | by
craig
Answered 822 days ago | Anonymous
|
|
|
Q: we have a Mira event XS thermastatis
Have you got enough hot water in your hot water cylinder? Also check inlet filters are clean.
|
|
|
Submitted 829 days ago | by
ian
|
|