Q: HAVE YOU THIS? Mira excel 410.32
|
|
|
Submitted 43 days ago | by
Werner Brunner, Schweiz
A: The link below shows all the parts available for this shower but the part number (410.32) does not exist on our system.
http://www.showerdoc.com/mira-parent-107-mira-excel-b---post-1996 Answered 43 days ago | Barrie
|
|
|
Q: i have fitted new carteidge to my mira excel shower but the water pressure has decreased significantly,what can cause this,and is there anything i can do to increase the pressure.
|
|
|
Submitted 108 days ago | by
jimbo, manchester
A: Thereis nothing that should cause this, however the cartridge has to be set for Highand Low pressure at the rear before fitting did you check this? Theother thing that it may be worth checking is the filters, sometimes turning thewater on and off can disturb any debris in the pipe work and this can getflushed through on to the filters Answered 107 days ago | The Doc
|
|
Q: dont know modle number how do i find out ? can i order new part to fix this .Thanks
|
|
|
Submitted 131 days ago | by
ve, wigan
Answered 130 days ago | The Doc
|
|
|
Q: My plumber tried to replace this cartridge with a new one. The new one keeps leaking, not through the shower head, but from behind/under the cartridge. Not sure where. 1 drip every few seconds. He took it in & out so many times, trying so many options I'm not sure what he was missing.
|
|
|
Submitted 155 days ago | by
Mark, Windsor UK
A: Generally there no problems fitting this cartridge. There is one thing that could be causing a problem however At the top and bottom of the cartridge there are twoletterbox shaped ‘O’ rings that fit into a recess in the cartridge body, the ‘O’rings are black as is the cartridge body. First check that the seals are in there, then check thatthere are not two seals in there! What can happen is when you change thecartridge over the original seal sticks to the shower body and you then offerup the new cartridge which has the seals in place, so you therefore end up withthe two seals together which will not allow the cartridge to sit properly. Answered 155 days ago | The Doc
|
|
Q: THE CONTROL KNOB DOESNT APPEAR TO CLOSE PROPERLY AND THE SHOWER IS NOW LEAKING ALL THE TIME.
IT FEELS LIKE A WASHER IS NEEDING REPLACED INSIDE THE KNOB, CAN A USELESS DIY PERSON CURE THIS.
|
|
|
Submitted 255 days ago | by
mossie, dundee
A: Hi It is the cartridge that has become faulty and will need replaced. To replace the cartridge Pre 2003 units Turn off hot and cold water supply Pull front temperature knob off The rest of the knob assy. just unclips Remove 4 screws that hold cartridge into body Pull old cartridge forward shouldn't be too tight Set new cartridge for High/Low pressure (instructions with cartridge) Slip new cartridge into place remember to check that the new seals are all in place (and don't drop out as you push back) Tighten screws be careful not to over tighten Refit knobs. Turn on water and test. (Occasionally you will have to reset the cartridge temperature, instructions with cartridge) Easy peasy!!!! Cartridge Mira 903.33 This cartridge supersedes the previous high and low pressure versions Link to cartridge http://www.showerdoc.com/shower-spares/mira/MIRA-903-33-Cartridge-Assembly-(Up-To-2003---Black)-Comes-with-seals Answered 255 days ago | The Doc
|
|
|
Q: I am after the part MIRA-410.52 but the photo looks incorrect to me. I am expecting this to be the same as MIRA-410.34 but in white. Can you confirm (or not) that MIRA-410.52 in is fact identical to MIRA-410.34 but in white? Many thanks.
|
|
|
Submitted 264 days ago | by
Steve, Dorset
A: Well spotted!!! The part number is correct however our ....and Mira’s image is wrong! The image should change in the next 24hrs if you order the part –you will get the correct part Thanks! Answered 263 days ago | The Doc
|
|
Q: Hi
I have a pre 1996 Mira Excel. We had it in the house we moved to and we have been there four years now. I have to be honest and say it has had some niggles with flow rates sometimes being slower than others and also the on of knob being stiff. However, it has now died. On off know turns, but no water. I have taken the front cover off and the teeth all look fine, but evening turning the cartrige manually gives no water. I can see that the mechanism moves in and out OK I am sure I was told we had a downstairs pump as we have an unvented system, but is there a way to identify if the pump or the Excel has a fault, as I don't want to buy one to find it's not at fault. Could there be a blockage
|
|
|
Submitted 304 days ago | by
Gareth, Poole
A: Hi If you have problems with an Excel then it's best just to replace the cartridge, however it is probably worth stripping the cartridge out and checking that the inlet filters are clean, before buying a new cartridge. Turn off hot and cold water supply Pull front temperature knob off The rest of the knob assy. just unclips Remove 4 screws that hold cartridge into body Pull old cartridge forward shouldn't be too tight Set new cartridge for High/Low pressure (instructions with cartridge) Slip new cartridge into place remember to check that the new seals are all in place (and don't drop out as you push back) Tighten screws be careful not to over tighten Refit knobs. Turn on water and test. (Occasionally you will have to reset the cartridge temperature, instructions with cartridge) Easy peasy!!!! Cartridge Mira 903.33 This cartridge supersedes the previous high and low pressure versions Answered 304 days ago | The doc
|
|
Q: the on off knob is very stiff as though something is catching inside
is it possible to strip the cartridge down to check inside
|
|
|
Submitted 467 days ago | by
johnb, newcastle
Answered 467 days ago | Alastair
|
|
Q: I need a new exposed hose connection for my Mira Excel are these available if not are there any that are compatible?
Many Thanks
Kerry
|
|
|
Submitted 499 days ago | by
kerry, dorset
Answered 498 days ago | LC
|
|
|
Q: I need the foam seals that fit round the white concealing plate no.410.53. i will have to buy the whole concealing plate to get these but on your price list the white version is £43.40 and the chrome version 410.54 is £19.64. Is this the correct price as every other chrome item on the page is alot more expensive than the white plastic version apart from these items where the reverse is true. Many thanks
|
|
|
Submitted 518 days ago | by
Jim, Lincoln
Answered 512 days ago | SD
|
|
|
Q: are these parts geuine mira excel parts
|
|
|
Submitted 597 days ago | by
chucky
A: In a word YES! 95% of the parts we supply are OME Answered 595 days ago | The Doc
|
|
Q: How do I adjust the temperature on a Mira excel?
I can only get cold water and the screens are clean!
Regards,
J D
|
|
|
Submitted 668 days ago | by
jimmydoc
A: Hi If you have problems with an Excel then it's best just to replace the cartridge, however it is probably worth stripping the cartridge out and checking that the inlet filters are clean, before buying a new cartridge. To replace the cartridge Pre 2003 units Turn off hot and cold water supply Pull front temperature knob off The rest of the knob assy. just unclips Remove 4 screws that hold cartridge into body Pull old cartridge forward shouldn't be too tight Set new cartridge for High/Low pressure (instructions with cartridge) Slip new cartridge into place remember to check that the new seals are all in place (and don't drop out as you push back) Tighten screws be careful not to over tighten Refit knobs. Turn on water and test. (Occasionally you will have to reset the cartridge temperature, instructions with cartridge) Easy peasy!!!! Cartridge Mira 903.33 This cartridge supersedes the previous high and low pressure versions Link to cartridge http://www.showerdoc.com/shower-spares/mira/MIRA-903-33-Cartridge-Assembly-(Up-To-2003---Black)-Comes-with-seals Answered 668 days ago | The Doc
|
|
Q: please advise if carrtridge assembly is still available for this
shower
thankyou
john m. williams
|
|
|
Submitted 717 days ago | by
jmw
Answered 716 days ago | Alastair
|
|
|
Q: My Mira Excel has completely packed up. I was looking to order a new cartridge and hope that this will work. Will this be easy enough for a complete novice to install ?
|
|
|
Submitted 755 days ago | by
RobW
A: Hi If you have problems with an Excel then it's best just to replace the cartridge, however it is probably worth stripping the cartridge out and checking that the inlet filters are clean, before buying a new cartridge. To replace the cartridge Pre 2003 units Turn off hot and cold water supply Pull front temperature knob off The rest of the knob assy. just unclips Remove 4 screws that hold cartridge into body Pull old cartridge forward shouldn't be too tight Set new cartridge for High/Low pressure (instructions with cartridge) Slip new cartridge into place remember to check that the new seals are all in place (and don't drop out as you push back) Tighten screws be careful not to over tighten Refit knobs. Turn on water and test. (Occasionally you will have to reset the cartridge temperature, instructions with cartridge) Easy peasy!!!! Cartridge Mira 903.33 This cartridge supersedes the previous high and low pressure versions Link to cartridge http://www.showerdoc.com/shower-spares/mira/MIRA-903-33-Cartridge-Assembly-(Up-To-2003---Black)-Comes-with-seals Answered 752 days ago | The Doc
|
|