A: You will have to check and see if it is the outlet pipe thatis leaking or the pressure relief device that has activated.
If it is the outlet pipe then you probably only need a newhose
I think the pressure relief device has blown.
It’s a safety device on the bottom of theheating tank.
It is fairly easy to replace however there isusually something that causes it to blow,
often a kink in the hose or the showerhead isblocked, so check this before fitting the new PRD.
http://www.showerdoc.com/TRITO-83301330-PRD-(Pressure-Relief-Device)-and-'O'-ring-(Pair)?ss=prd&pg=2
Answered 15 days ago | The doc