Q: MyTriton rapid3+ shower stopped working after making a rumbling noise and tripped the RCD. It still runs cold water but trips each time you turn on the heat. I have tested the solenoid as described in prev post and think it is ok., So what else could it be?
Thanks
|
|
|
Submitted 24 days ago | by
Dyer, Bristol, England
A: Itmay be a faulty element in the heating tank (there are two, three inmost 10kw showers) you can check them with a multi meter you should havea reading of around 12>18 ohms. Ifyou have power to the elements and no heat it's probably the elements,no power to the elements then it's probably a micro switch.
Ifyou don’t have a multimeter we sell them at £10 each with a guide onhow to use them for checking and testing the various parts of yourshower.
Apartfrom helping to fix your shower, they are really useful for checkingyou have a power supply to appliances, for checking fuses, letting youknow much power you have left in batteries (so you know if they are dud or not) and lots of other jobs, in short they are well worth the £10.
http://www.showerdoc.com/installation/electrical-products/SKYTRO-600-005-Digital-Multi-Tester Answered 24 days ago | Barrie
|
|
|
Q: my pressure light comes on when I turn the shower off. The water gets hot and the water flows ok.
|
|
|
Submitted 30 days ago | by
georgie, Gwent
A: Forgettingabout the temperature turn the shower from fully hot to fully cold atfully hot you should have not much more than a dribble coming from thehose and on fully cold you should have a good strong flow, if you do nothave this difference then you may have a faulty flow/stabilizer valve. Answered 30 days ago | Barrie
|
|
Q: When I press the stop button my shower will not turn off
The only way I can stop the water is close the stop cock
I have just cleaned the inlet pipe as it was blocked up
Could the increase in pressure blown something else
|
|
|
Submitted 35 days ago | by
Evo, Walsall
A: It may be your solenoid valve, you can check it if you have a multi meter, you should have a reading of at least k3.5 ohms, across the two terminals any less and you need a new valve. (Check the valve in the failed state.) (When it has stopped working!) If there is power getting to the solenoid and it is not operating then there is a good chance that you have a faulty solenoid. http://www.youtube.com/watch?v=NzJjzWqxesc The video is intended as a guide and does not cover every shower. If you don’t have a multimeter we sell them with a guide on how to use them for checking and testing the various parts of your shower. Apart from helping to fix your shower, they are really useful for checking you have a power supply to appliances, for checking fuses and letting you know much power you have left in batteries (So you will know if they are good or not) and lots of other jobs, in short they are well worth a few pounds http://www.showerdoc.com/installation/electrical-products/SKYTRO-600-005-Digital-Multi-Tester Answered 33 days ago | Barrie
|
|
|
Q: Do you know what part number is it?
|
|
|
Submitted 82 days ago | by
scarlett, derbyshire
A: http://www.showerdoc.com/shower-accessories/shower-hoses/triton/TRITO-28100260-Triton-Flexible-Hose-1-75m-(chrome)-28100260
Depending on the length it could be this one. Answered 82 days ago | Barrie
|
|
|
Q: The water temperature is cold until turned completly up, then the water is luke warm!
|
|
|
Submitted 115 days ago | by
chris, kendal
A: We are having a problem at the moment with our ticketing systemit is running words together, we have people working on it!! It maybe a faulty element in the heating tank (there are two, three in most 10kwshowers) you can check them with a multi meter you should have a reading ofaround 12>18 ohms. If you have power to the elementsand no heat it's probably the elements, no power to the elements thenit's probably a micro switch. If you don’t have amultimeter we sell them at £10 each with a guide on how to use them forchecking and testing the various parts of your shower. Apart from helping to fix yourshower, they are really useful for checking you have a power supply to appliances,for checking fuses, letting you know much power you have left in batteries (so you know if they are dud ornot) and lots of other jobs, in short they are well worth the £10. http://www.showerdoc.com/installation/electrical-products/SKYTRO-600-005-Digital-Multi-Tester Answered 115 days ago | The Doc
|
|
|
Q: Hi, our Triton Rapide 3 plus, has started cutting off whilst we are showering. It blows the fuse in the mains box. Is there anything we can do to fix it. Thanks
|
|
|
Submitted 172 days ago | by
Jelly, Gtr Manchester UK
A: According to your description of the fault it sounds like a faulty solenoid valve (See below for how to check) there could be one or two other possibilities however we need to make sure that the solenoid is OK in the first instance. It may be your solenoid valve, you can check it if you have a multi meter, you should have a reading of at least k3.5 ohms, across the two terminals any less and you need a new valve. (Check the valve in the failed state.) (When it has stopped working!) If there is power getting to the solenoid and it is not operating then there is a good chance that you have a faulty solenoid. http://www.youtube.com/watch?v=NzJjzWqxesc The video is intended as a guide and does not cover every shower. If you don’t have a multimeter we sell them with a guide on how to use them for checking and testing the various parts of your shower. Apart from helping to fix your shower, they are really useful for checking you have a power supply to appliances, for checking fuses and letting you know much power you have left in batteries (So you will know if they are good or not) and lots of other jobs, in short they are well worth a few pounds http://www.showerdoc.com/installation/electrical-products/SKYTRO-600-005-Digital-Multi-Tester Answered 171 days ago | The Doc
|
|
|
Q: what are the diamentions of this shower?
|
|
|
Submitted 217 days ago | by
Anonymous, uk
A: 305mm high X 210mm wide Answered 215 days ago | The Doc
|
|
|
Q: can I buy a replacement.
|
|
|
Submitted 307 days ago | by
pops, runcorn cheshire
Answered 306 days ago | The Doc
|
|
Q: After a few months of water going hot cold hot cold my shower finally gave up the ghost and water shot out of the small spout at the bottom with nothing out of the head. Im due to rip out the whole bathroom next year. Can i keep this shower going? I have the skill to replace parts oh whole same model if i have to.
Cheers
|
|
|
Submitted 326 days ago | by
Phill, Oxford
A: Hi I think the pressure relief device has blown. It’s a safety device on the outlet pipe. It is fairly easy to replace however there is usually something that causes it to blow, often a kink in the hose or the showerhead is blocked, so check this before fitting the new PRD. http://www.showerdoc.com/shower-spares/triton/TRITO-82800450-Triton-Pressure-Relief-Device-82800450 The hot cold cycling may also be some of the problem The things to check first are.
1 That the main valve coming into your house is fully open.
2 Then check that the valve on the line to the shower is fully open.
If these valves are not fully open then there may not be enough water getting to your shower to cool it properly the overheat safety device will turn the power off until it cools Then it all starts again
Make sure that the shower head is clean and clear, that the hose isn’t kinked (this can happen just behind the hand set where it is difficult to see) also check the inside of the hose although it can look OK on the outside it could have collapsed internally
Answered 326 days ago | The Doc
|
|
Q: I have a Triton Rapid 3+ shower. On two occassions the shower has just turned itself off mid shower.
The pressure coloured indicator is then red.
It will not restart up for a while later.
What could it be?
Thanks
|
|
|
Submitted 334 days ago | by
kingy1, Manchester
A: It may be your solenoid valve, you can check it if you have a multi meter, you should have a reading of at least k3.5 ohms, across the two terminals any less and you need a new valve. (Check the valve in the failed state.) (When it is not working!) If there is power getting to the solenoid and it is not operating then there is a good chance that you have a faulty solenoid. If you don’t have a multimeter we sell them with a guide on how to use them for checking and testing the various parts of your shower. Apart from helping to fix your shower, they are really useful for checking you have a power supply to appliances, for checking fuses and letting you know much power you have left in batteries (So you will know if they are good or not) and lots of other jobs, in short they are well worth a few pounds http://www.showerdoc.com/installation/electrical-products/SKYTRO-600-005-Digital-Multi-Tester Answered 334 days ago | The Doc
|
|
Q: Hi I am going to replace my rapide2+ shower and am wondering if i can obtain an original or direct replacement.
Thank you,
B Cotton
|
|
|
Submitted 364 days ago | by
gremlin, Peterborough pe46qj
Answered 360 days ago | Alastair
|
|
|
Q: i require on off switch for rapid 3+can i use something else off another model
|
|
|
Submitted 470 days ago | by
taggart, blackpool
Answered 470 days ago | Alastair
|
|
|
Q: Triton rapide 3+ it started cutting off the water flow to the head when used but came back when switched off or left for a while. It has now shut off & will not start again when the switch is pressed.
|
|
|
Submitted 555 days ago | by
cooperman
A: It may be your solenoid valve, you can check it if you have a multi meter, you should have a reading of at least k3.5 ohms, across the two terminals any less and you need a new valve. (Check the valve in the failed state.) (When it is not working!) If there is power getting to the solenoid and it is not operating then there is a good chance that you have a faulty solenoid. If you don’t have a multimeter we sell them with a guide on how to use them for checking and testing the various parts of your shower. Apart from helping to fix your shower, they are really useful for checking you have a power supply to appliances, for checking fuses and letting you know much power you have left in batteries (So you will know if they are good or not) and lots of other jobs, in short they are well worth a few pounds http://www.showerdoc.com/installation/electrical-products/SKYTRO-600-005-Digital-Multi-Tester Answered 555 days ago | Anonymous
|
|
Q: My Triton Rapide 3+ shower has recently been relocated and now the water temperature fluctuates from very hot to very cold within a period of 2 minutes or so and it cannot be regulated properly. The shower is working fine apart from this complaint.
I look forward to receiving your advice as to which parts require replacement as previous advice and sales support with my Mira Sport shower has been invaluable over the last 8 or so years.
Ciao, John
|
|
|
Submitted 581 days ago | by
WotNotAgain
A: The things to check first are.
1 That the main valve coming into your house is fully open.
2 Then check that the valve on the line to the shower is fully open.
3 And in your case when it was relocated was it connected to the water mains?
If these valves are not fully open then there may not be enough water getting to your shower to cool it properly the overheat safety device will turn the power off until it cools Then it all starts again
Make sure that the shower head is clean and clear, that the hose isn’t kinked (this can happen just behind the hand set where it is difficult to see) also check the inside of the hose although it can look OK on the outside it could have collapsed internally
Also as it is a Triton have a look at the outlet TCO
The outlet Thermal Cut Out this is a black disk with two wires going to it and it is mounted on the out let pipe (The bit between the heating tank and the hose) Examine the connections closely if you see any discoloration / signs of overheating then the TCO needs replaced. Answered 579 days ago | The Doc
|
|