Q: why does my shower leak from the overflow pipe
|
|
|
Submitted 118 days ago | by
Anonymous, wolverhampton
A: We are having a problem at the moment with our ticketing systemit is running words together, we have people working on it!! I think the pressure relief device has blown. It’s a safety device on the bottom of theheating tank. It is fairly easy to replace however there isusually something that causes it to blow, often a kink in the hose or the showerhead isblocked, so check this before fitting the new PRD. http://www.showerdoc.com/TRITO-83301330-PRD-(Pressure-Relief-Device)-and-'O'-ring-(Pair)?ss=prd&pg=2 Answered 117 days ago | The Doc
|
|
|
Q: when i turn shower on water comes back up the shower hose. when i remove shower head all is fine tried with new shower head still the same can you help
|
|
|
Submitted 119 days ago | by
andy, romford essex
A: Iam not sure I understand what you mean, do you mean that the shower hose doesn’tleak when you remove the head .....If this is the case then it is probably justthe hose that needs tightened or a new hose washer fitted. Answered 117 days ago | The doc
|
|
|
Q: the pressure light comes on straight away it goes straight to cold but it still letts water threw. i have tested the tco and that is working but still replaced it anyway. can you suggest what i try next please
|
|
|
Submitted 120 days ago | by
pegleg, northampton
A: The things to check first are.
1 That the main valve coming into your house is fully open.
2 Then check that the valve on the line to the shower is fully open.
If these valves are not fully open then there may not be enough water getting to your shower to open / close the safety device that allowspower through to the elements The first things to check are: 1 That the main valve coming into your house is fullyopen. 2 Then check that the valve on the line to the shower isfully open. If these valves are not fully open then there may not be enoughwater getting to your shower to open the pressure switch therefore nopower will get to the elements and the unit will show lowpressure. Forgetting about the temperature turn the shower from fully hotto fully cold at fully hot you should have not much more than a dribble comingfrom the hose and on fully cold you should have a good strong flow, if you donot have this difference then you may have a faulty flow/stabilizer valve Finally when you turn thewater on, the top of the flow valve should rise, there is a plastic actuator ontop of the valve this should press against a micro switch at the bottom of thePCB make sure they are properly aligned. If all these are OK then youprobably have a fault with your PCB. The checks don’t guarantee that you have a faulty power PCBhowever they do eliminate just about every thing that could cause the lowpressure fault and so the only thing left is the PCB. Answered 117 days ago | The Doc
|
|
|
Q: My shower is saying low pressure and running hot and cold, had a plumber out and he said its the medium element that is not working could you please advise me which item to order thanks
|
|
|
Submitted 120 days ago | by
fefo, glasgow
A: The things to check first are.
1 That the main valve coming into your house is fully open.
2 Then check that the valve on the line to the shower is fully open.
If these valves are not fully open then there may not be enough water getting to your shower to cool it properly the overheat safety devicewill turn the power off until it cools Then it all starts again Make sure that the shower headis clean and clear, that the hose isn’t kinked (this can happen just behind thehand set where it is difficult to see) also check the inside of the hosealthough it can look OK on the outside it could have collapsed internally
See below for how to test the element. It maybe a faulty element in the heating tank (there are two, three in most 10kwshowers) you can check them with a multi meter you should have a reading ofaround 12>18 ohms. If you have power to the elementsand no heat it's probably the elements, no power to the elements thenit's probably a micro switch. If you don’t have amultimeter we sell them at £10 each with a guide on how to use them forchecking and testing the various parts of your shower. Apart from helping to fix yourshower, they are really useful for checking you have a power supply to appliances,for checking fuses, letting you know much power you have left in batteries (so you know if they are dud ornot) and lots of other jobs, in short they are well worth the £10. http://www.showerdoc.com/installation/electrical-products/SKYTRO-600-005-Digital-Multi-Tester If it is a faulty element then you will need a new heating tank(Part 5 or 6) depending on the rating of the existing tank. http://www.showerdoc.com/trito-parent-84-triton-martinique Answered 117 days ago | The doc
|
|
|
Q: when shower is switched off water still runs through the shower i have to turn main supply of water off to stop it and turn it on when shower neede
|
|
|
Submitted 145 days ago | by
ilton25, ilminster
A: Youwill need to replace the solenoid valve Answered 143 days ago | The Doc
|
|
|
Q: the showerhead holder does not hold the shower head very well as the head pops out despite being properly located, it would appear that the recess requires to be slightly larger in order to recess the shower head deeper into the holder, Is it possible to purchase a slightly wider locator?
|
|
|
Submitted 180 days ago | by
candy, ayr scotland
Answered 173 days ago | The doc
|
|
|
Q: When I switch the shower on it appears to be leaking from somewhere around the top of the stabiliser valve. However, if I switch the shower off and then back on again, the leak stops and doesn't start again while it is running. Any ideas, and how easy is it to replace the likely faulty parts?
|
|
|
Submitted 192 days ago | by
Captain, Birmingham
Answered 191 days ago | The Doc
|
|
Q: Is this model(and water/electric inlet hole) a direct swop for the original Opal model?
If the water/electric inlet hole is in a different position can you suggest an alternative so as to avoid unsightly gaps etc and the re-tiling
|
|
|
Submitted 227 days ago | by
Derek, west Midlands
A: Yes this would be a direct swap However I think that the Martinique is now unavailable. Answered 227 days ago | The doc
|
|
|
Q: My shower keeps switching from hot to cold by itself whilst being left at the same settings.What is likely to be the component causing this problem.
|
|
|
Submitted 248 days ago | by
Dot, N/Ireland
|
|
Q: the shower has stopped working.
The pressure light comes on immediately and no water passes through. What could be the problem as there has been no reduction in water pressure?
|
|
|
Submitted 294 days ago | by
Nigel, Bolton
A: The first things to check are: 1 That the main valve coming into your house is fully open. 2 Then check that the valve on the line to the shower is fully open. If these valves are not fully open then there may not be enough water getting to your shower to open the pressure switch therefore no power will get to the elements and the unit will show low pressure. The other possibility is a faulty Thermal Cut Out
A faulty TCO will have no continuity across the two terminals (The black thing on top of the heating tank)
Therefore a good TCO will have power at both connections and a faulty TCO will have power at only one.
(The function of the TCO is, if the water over heats it cuts the power off to the elements) See Video. http://www.youtube.com/user/showerdoc#p/u/2/_zi8JbEMYMs The checks don’t guarantee that you have a faulty power PCB however they do eliminate just about every thing that could cause the low pressure fault and so the only thing left is the PCB. Answered 292 days ago | The Doc
|
|
|
Q: I am looking for a new holder for my trition martinique shower, i thought this might be the one - Triton Showerhead Holder 22mm White 83313470. it has a different fitting at the side. Is the old part now obselete. i thought ot was 83306190
|
|
|
Submitted 324 days ago | by
hammer, belfast
A: The Triton Martinique has had several different holder over the years and most of them have been superseded by others. They used to come with the 83306190 or the 22010980 , This 83313470 is the replacement and is used for most 22mm diameter triton rails so this would fit and its quite robust. This part can be found via this link provided - http://www.showerdoc.com/trito-83313470-triton-showerhead-holder-22mm-white-83313470 Answered 324 days ago | LC
|
|
|
Q: Have just replaced Triton martinique 10.5 kw as it stopped working completely. Installed exactly the same model but pressure light comes on if try to lower temperature and reverts to cold only. Have tested pressure at mains and is 3 bar.
|
|
|
Submitted 325 days ago | by
dcooper, London
A: The things to check first are.
1 That the main valve coming into your house is fully open.
2 Then check that the valve on the line to the shower is fully open.
If these valves are not fully open then there may not be enough water getting to your shower to open / close the safety device that allows power through to the elements
In your case it may be that you have the pressure but if the valves are half closed they may be restricting the flow. Answered 324 days ago | The Doc
|
|
Q: Pressure light comes on and off, works one minute next light comes on and shower goes cold. Has it happens I have the same shower unit in my second bathroom which works fine. so can't be a water pressure problem it don't think?
Is this a common fault and what part do I require to fix it.... Thanks
|
|
|
Submitted 360 days ago | by
Ray, Worcestershire
Answered 360 days ago | Alastair
|
|
|
Q: hi,shower was making a buzzing sound,then the pressure light came on and it stopped workin.when switched on it now clicks then the pressure light comes on and it goes to cold setting,what part would i need?
|
|
|
Submitted 377 days ago | by
jdegg, cannock
A: I think you may have a faulty Thermal Cut Out
A faulty TCO will have no continuity across the two terminals (The black thing on top of the heating tank)
Therefore a good TCO will have power at both connections and a faulty TCO will have power at only one.
(The function of the TCO is, if the water over heats it cuts the power off to the elements) See Video. http://www.youtube.com/user/showerdoc#p/u/2/_zi8JbEMYMs Also check
1 That the main valve coming into your house is fully open.
2 Then check that the valve on the line to the shower is fully open.
3 Make sure that the shower head is clean and clear, that the hose isn’t kinked (this can happen just behind the hand set where it is difficult to see) also check the inside of the hose although it can look OK on the outside it could have collapsed internally
It may be some other fault but we need to get these checks out of the way first
Answered 375 days ago | The Doc
|
|
|
Q: my triton martinique shower runs for about 10 minutes and trips out on the fuse board i have checked all connections they seem ok i have a 40amp trip on a seperate line and this feels warm when checked when cooled i can switch it back on the same will hapen again
|
|
|
Submitted 418 days ago | by
jono, harlow
A: Sounds like you have the 10.5 version of the Martinique which requires a 45amp fuse depending on the age of your board you may just be able to change the fuse. Answered 417 days ago | The Doc
|
|
Q: There is a little pipe behind where the shower hose fits to the unit and when the shower is turned on the water comes out of that pipe and not through the hose as it should do. How do I repair this? Do I need any new components?
Any help would be much appreciated.
Thanks
Rosie
|
|
|
Submitted 435 days ago | by
Robot, Bristol
Answered 432 days ago | The Doc
|
|
Q: How much do these cost and are they easy to replace?
cheers barry
|
|
|
Submitted 462 days ago | by
barry, essex
Answered 462 days ago | Alastair
|
|
|
Q: my triton martinique temperature has gone very cold i have to have it on nearly ten for it to be hot what could this be??
|
|
|
Submitted 468 days ago | by
barry, essex
A: It may be a faulty element in the heating tank (there are two, three in most 10kw showers) you can check them with a multi meter you should have a reading of around 12>18 ohms. If you have power to the elements and no heat it's probably the elements, no power to the elements then it's probably a micro switch. If you don’t have a multimeter we sell them at £10 each with a guide on how to use them for checking and testing the various parts of your shower. Apart from helping to fix your shower, they are really useful for checking you have a power supply to appliances, for checking fuses, letting you know much power you have left in batteries (so you know if they are dud or not) and lots of other jobs, in short they are well worth the £10. http://www.showerdoc.com/installation/electrical-products/SKYTRO-600-005-Digital-Multi-Tester Answered 467 days ago | The Doc
|
|
|
Q: when the shower is switched on it gets to the correct temperature then the middle light (cold) come's on and it run's cold,then this light goes off and it to the right temaerature again and this keep's happening.i've changed the solenoid coil and it's still happening,any idea's...
|
|
|
Submitted 491 days ago | by
m8r98ret, northampton
Answered 489 days ago | Alastair Answered 489 days ago | Alastair Answered 489 days ago | Alastair
|
|